Before work starts
The technician explains the work and agrees the cost with you before starting. A final figure comes after the range, oven or grill has been looked at in person.
Independent appliance repair
We repair Viking undercounter ice machines, clear and nugget, including the 5 Series FGIM and FNIU515D and the professional FIUI5152D: ice that is small or missing, a Time to Clean or CL signal, Er codes or water on the floor. Book a technician.


On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.

Gray, smelly or off-tasting ice from a Viking ice machine usually means mineral scale on the evaporator, hard water, food stored in the bin or an old charcoal filter. Clean the machine, empty the bin of anything but ice and consider a filter. Call us if the taste stays after cleaning.
CL alternating with ICE on a Viking FIUI5152D undercounter ice machine appears every 3000 cycles to say the unit needs cleaning. The reminder resets once the machine has finished its cleaning cycle.
Er01 on a Viking FNIU515D nugget ice machine means the evaporator is still 32 F or warmer after 30 minutes of ice making. The chart lists a refrigerant leak check, a sensor check, and restoring power once the cooling problem is solved.
Er03 on a Viking FNIU515D nugget ice machine is an evaporator temperature error: 32 F or more after 10 minutes of ice making. The chart lists the same actions as for Er01.
Er15 on a Viking FNIU515D nugget ice machine is a water supply error: the water level sensor found no water for 2 minutes. The chart lists a water supply pressure check and a water level sensor check, then restart.
Er16 on a Viking FNIU515D nugget ice machine is a water drain error: the lower limit water level sensor did not detect water within 2 minutes of the drain valve operating. The chart lists replacing the sensor and checking the drain valve.
Er25 on a Viking FNIU515D nugget ice machine is an evaporator freezing error: the outlet temperature dropped below its set point for 2 minutes while ice was being made. The chart says it occurs when the ambient temperature is low and that the machine should run above 50 F.
Which part is needed gets decided on site, once the label is read and the diagnostic is done. We buy nothing in advance, and you say yes to the price before the work starts.

A Viking 5 Series nugget ice machine (FNIU515D) removes melt water with a drain pump that has its own reservoir. The pump turns on by itself as the reservoir fills, even in Sabbath mode. The Drain lamp lights when the drain valve opens, and Er16 means the water level sensor was not reached within 2 minutes of draining.

Viking 5 Series clear and nugget ice machines are cooled by a condenser the guides compare to a car radiator: fins and tubes that clog with dirt and lint. The Time to Clean light comes on after 6 months of use. For low capacity, the troubleshooting guide says to clean the air-cooled condenser fins.

The FNIU515D nugget ice machine uses a water level sensor to confirm water is arriving and draining. If no level is detected for 2 minutes of water supply, the display shows Er15; if the lower limit is not detected within 2 minutes of draining, it shows Er16. The table lists a water supply pressure check and a sensor check as the action.
How a visit runs.
You know the plan before we arrive.

Pick the range, grill or other appliance and tell us what it does. Add the model number if you can find it.

The technician tests igniters, gas flow and controls, then talks through the findings and agrees the cost with you before any work starts.

After the repair, the technician runs the appliance through its paces and explains what changed.
CL alternates with ICE on the FIUI5152D every 3000 cycles. Time to Clean lights after 6 months on the 5 Series clear and nugget machines.
Scale remover, a flush and a sanitize of the bin, per your guide.
Low capacity can mean dirty condenser fins; clean without denting them.
Check Water blinking means look at the supply. The nugget FNIU515D prints Er15 for supply and Er16 for drain.
Wine or beer bottles can plug the drain with slipped labels.
An Er code returns after the supply and drain are clear.
Cubes stay ragged after scale removal.
CL or Time to Clean returns right after cleaning.
Water pools in the bin or on the floor.
Arrange a diagnosticThe technician explains the work and agrees the cost with you before starting. A final figure comes after the range, oven or grill has been looked at in person.
Anything covered by Viking's manufacturer warranty is handled by Viking itself. Our own repairs come with a warranty on the workmanship.
No. Clear, nugget and professional undercounter machines are all on this one page.
On the FIUI5152D, CL alternates with ICE every 3000 cycles to ask for cleaning. It is not the refrigerator condenser reminder.
The supply check: the control looks for water every 20 minutes and restarts when it returns.
Water supply and water drain errors on the FNIU515D nugget machine.
Inside the manufacturer’s coverage period, a repair on your Viking is theirs to handle. After it lapses, or if you favor an independent technician, schedule with us and hear the price first.
Viking codes, symptoms, parts, visits
CL alternating with ICE on a Viking FIUI5152D undercounter ice machine appears every 3000 cycles to say the unit needs cleaning. The reminder resets once the machine has finished its cleaning cycle.
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.
A Viking 5 Series nugget ice machine (FNIU515D) removes melt water with a drain pump that has its own reservoir. The pump turns on by itself as the reservoir fills, even in Sabbath mode. The Drain lamp lights when the drain valve opens, and Er16 means the water level sensor was not reached within 2 minutes of draining.
Book a diagnostic for your series at the appliance itself.
Office particulars and the entry details to give us.