What it means
CL alternating with ICE on a Viking FIUI5152D undercounter ice machine appears every 3000 cycles to say the unit needs cleaning. The reminder resets once the machine has finished its cleaning cycle.
Viking ice maker CL / Maintenance reminder
CL alternating with ICE on a Viking FIUI5152D undercounter ice machine appears every 3000 cycles to say the unit needs cleaning. The reminder resets once the machine has finished its cleaning cycle.
Also shown as CL
CL alternating with ICE on a Viking FIUI5152D undercounter ice machine appears every 3000 cycles to say the unit needs cleaning. The reminder resets once the machine has finished its cleaning cycle.
Follow the cleaning section of the manual.
CL returns right after a full cleaning cycle.
Your Viking checklist, kept on this device only

Follow the cleaning section of the manual.

The manual calls for a measured amount of cleaner on the evaporator plate.

The reminder resets after the cleaning cycle completes.

If CL returns right after a full cycle, book a visit.
Pass along the model and the checks you ran, then open a visit request from this spot.
Book a visit

A simplified sketch, because the inside of a Viking differs by series. Tap a highlighted part for its photo and the matching test.

Component reference
Viking 5 Series clear and nugget ice machines are cooled by a condenser the guides compare to a car radiator: fins and tubes that clog with dirt and lint.
Read the definitionEvery 3000 cycles, alternating with ICE.
Read the supporting manualNo; that one asks for condenser cleaning on a 7 Series model.
Read the supporting manualFinish the cleaning cycle.
Read the supporting manualManufacturer document
Viking Range, LLC (official manual PDF)
printed code (091426) / PDF p.22
Source: the Viking FIUI5152D undercounter ice machine manual, p. 22.
No, it is a reminder. CL alternates with ICE every 3000 cycles to say the machine needs cleaning, and it resets once the cleaning cycle has finished.
The manual ties the reminder to cycles, so clean soon rather than letting it run on. Finish the full cleaning cycle with the cleaner measured as the manual directs.
Behind the fascia door, per the manual. That is where the measured amount of cleaner goes, on the evaporator plate, as the cleaning section describes.
Book a visit if CL comes straight back after a full cleaning cycle. The refrigerator CL is a different reminder, for condenser cleaning, so do not mix the two.
Viking codes, symptoms, parts, visits
The Time to Clean light on a Viking 5 Series 15 in ice machine comes on after 6 months of use. Clean the ice making system. It is a reminder, not a breakdown.
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.
Viking 5 Series clear and nugget ice machines are cooled by a condenser the guides compare to a car radiator: fins and tubes that clog with dirt and lint. The Time to Clean light comes on after 6 months of use. For low capacity, the troubleshooting guide says to clean the air-cooled condenser fins.
Book a diagnostic for your series at the appliance itself.
Office particulars and the entry details to give us.