Start from the symptom
Viking ice maker not making ice.
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.

Start with safe observations.
Turn the appliance off and unplug it before any check you can make yourself. Beware of standing water and sharp edges. Never touch a wet plug or live wiring, take off service panels, or go beyond what your series' guide allows.
- 1
Switch and control
Check the On/Off switch and that the electronic control is in the ICE position. Also check the breaker, since a tripped circuit stops the machine without any message.
- 2
Water supply
The guides list a closed water valve, a blown fuse, a kinked supply line and low pressure. On nugget and clear ice models a flashing blue Check Water light means the water supply needs attention; the machine rechecks every 20 minutes.
- 3
Warm-up time
A typical ice cycle can take up to 1½ hours and a first start longer. The FIUI5152D guide says to check the bin after 24 hours.
- 4
Drain and plug
Check the reservoir drain plug is seated and that the drain is not restricted. A drain pump can shut the unit off for a few minutes when it sees a high water level.
- 5
Airflow and room
The front grille must be open for condenser airflow. The guide asks for a room below 90°F for built-in and below 100°F for freestanding, and above 55°F so the bin thermistor does not stop it.
- 6
Clean the system
Scale on the evaporator or a restricted distributor tube cuts ice. Run a cleaning cycle and check any water filter for restrictions.
Systems a technician may investigate.
The parts below connect to this symptom. Seeing it does not establish that any one of them is the culprit.

Water level sensor and Er15 / Er16
The FNIU515D nugget ice machine uses a water level sensor to confirm water is arriving and draining. If no level is detected for 2 minutes of water supply, the display shows Er15; if the lower limit is not detected within 2 minutes of draining, it shows Er16. The table lists a water supply pressure check and a sensor check as the action.

Drain pump and drain lamp
A Viking 5 Series nugget ice machine (FNIU515D) removes melt water with a drain pump that has its own reservoir. The pump turns on by itself as the reservoir fills, even in Sabbath mode. The Drain lamp lights when the drain valve opens, and Er16 means the water level sensor was not reached within 2 minutes of draining.

Air-cooled condenser and Time to Clean
Viking 5 Series clear and nugget ice machines are cooled by a condenser the guides compare to a car radiator: fins and tubes that clog with dirt and lint. The Time to Clean light comes on after 6 months of use. For low capacity, the troubleshooting guide says to clean the air-cooled condenser fins.
When observation becomes a service request.
Leave internal testing to a technician.
The Check Water light stays on with water confirmed at the machine.
The machine shows Er01, Er03, Er15, Er16 or Er25.
The drain pump runs but no water leaves, or it cycles on and off.
No ice after 24 hours with a clean machine and water at the valve.
Arrange a diagnosticSources and model boundaries.
The Viking ice maker not making ice guidance rests on these references. Choose the manual that fits your own series.
- Install / Use & Care MANUAL / Professional Undercounter Ice Machine / FIUI5152D
- Use & Care / 5 SERIES / 15"W. Undercounter/Freestanding Nugget Ice Machine
- Use & Care / 15"W. Undercounter/Freestanding Ice Machine / FGIM5151 FPIM5151
Rely on the guide for your precise series, and read how we research these pages.
When does a new ice machine start producing?
The FIUI5152D guide says a typical production cycle can take up to 1½ hours, and the first start longer. Check the bin for ice after 24 hours.
What does the blue Check Water light mean?
On the nugget and clear ice models it means water is not reaching the machine. The control checks every 20 minutes and restarts ice making when water returns.
What is the minimum room temperature?
The FIUI5152D guide gives 55°F. Below that, the bin thermistor can read the room as cold and stop production before the bin fills, and a restart may not happen.
Can I fix a drain pump problem myself?
Only the simple checks: power, plug, debris at the inlet, kinks in the vent line and discharge tubing within 8 feet of lift and 20 feet of run. Plumbing outside the machine needs a plumber.
Viking codes, symptoms, parts, visits
From the message to your next move.
Check Water
A flashing blue Check Water light on a Viking 5 Series 15 in ice machine means check the water supply. The control checks for water every 20 minutes and restarts ice making by itself once water returns.
Viking ice maker not making ice
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.
Drain pump and drain lamp
A Viking 5 Series nugget ice machine (FNIU515D) removes melt water with a drain pump that has its own reservoir. The pump turns on by itself as the reservoir fills, even in Sabbath mode. The Drain lamp lights when the drain valve opens, and Er16 means the water level sensor was not reached within 2 minutes of draining.
Ice maker repair
Book a diagnostic for your series at the appliance itself.
Find your metro