What it means
Er03 on a Viking FNIU515D nugget ice machine is an evaporator temperature error: 32 F or more after 10 minutes of ice making. The chart lists the same actions as for Er01.
Viking ice maker Er03 / Evaporator temperature
Er03 on a Viking FNIU515D nugget ice machine is an evaporator temperature error: 32 F or more after 10 minutes of ice making. The chart lists the same actions as for Er01.
Also shown as Er03
Er03 on a Viking FNIU515D nugget ice machine is an evaporator temperature error: 32 F or more after 10 minutes of ice making. The chart lists the same actions as for Er01.
Er03 and the 10-minute condition.
Er03 returns after the checks.
Your Viking checklist, kept on this device only

Er03 and the 10-minute condition.

Stop ice making.

Refrigerant work is for a technician.

The chart actions are service steps.
Pass along the model and the checks you ran, then open a visit request from this spot.
Book a visit

A simplified sketch, because the inside of a Viking differs by series. Tap a highlighted part for its photo and the matching test.
The evaporator temperature was 32 F or more after 10 minutes of ice making. The actions are the same three as for Er01: check refrigerant leakage, check the sensor and attachment, and resupply power after the cooling problem is resolved.
Read the supporting manualFor Er03 the ICE lamp blinks on its own. The chart shows Er01 with ICE, NO WATER and DRAIN all blinking, so the lamps tell you which of the two is active.
Read the supporting manualNo. A slow ICE lamp (on for 2 seconds, off for 1) means the storage bin is full. The chart also shows the ICE lamp blinking once a second while the unit is washing. Check the speed and the other two lamps.
Read the supporting manualManufacturer document
Viking Range, LLC (official manual PDF)
Rev C, printed code (051525) / PDF pp.16–17
Source: the Viking FNIU515D undercounter nugget ice machine manual, p. 17.
Bin full is a slow pattern, on for 2 seconds and off for 1, and the lamp goes out when the sensor sees the release temperature. Er03 blinks the ICE lamp as an error.
The chart does not explain the choice. It prints the two thresholds and the same actions.
The chart says to resupply power after the cooling problem is resolved. Power alone does not resolve it.
That one blinks once a second and stops when the operation switch goes to off. It is a normal washing state, not an error.
Viking codes, symptoms, parts, visits
Er01 on a Viking FNIU515D nugget ice machine means the evaporator is still 32 F or warmer after 30 minutes of ice making. The chart lists a refrigerant leak check, a sensor check, and restoring power once the cooling problem is solved.
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.
Book a diagnostic for your series at the appliance itself.