What it means
A Viking FNIU515D that blinks ICE and NO WATER in step is pointing at the evaporator outlet sensor, which the chart calls disconnected or shorted. Its action: check the sensor and how it is attached, then restart after the repair.
Viking ice maker ICE and NO WATER lamps blinking / Temperature sensors
A Viking FNIU515D that blinks ICE and NO WATER in step is pointing at the evaporator outlet sensor, which the chart calls disconnected or shorted. Its action: check the sensor and how it is attached, then restart after the repair.
Also shown as ICE and NO WATER lamps blinking
A Viking FNIU515D that blinks ICE and NO WATER in step is pointing at the evaporator outlet sensor, which the chart calls disconnected or shorted. Its action: check the sensor and how it is attached, then restart after the repair.
ICE and NO WATER blink while DRAIN stays dark.
The two lamps are back once the machine has been restarted.
Your Viking checklist, kept on this device only

ICE and NO WATER blink while DRAIN stays dark. If DRAIN joins in, you are on the Er01 evaporator temperature row instead.

Leave the mode switch on off for a short spell, then go back to ice. That can clear a stray reading, though it cannot repair a sensor that is genuinely open.

Here the NO WATER lamp is just one half of the pattern. It does not say the supply line is shut, so skip the valves and filters.

The chart asks for a check of the sensor and its attachment and a restart after the sensor part is repaired. That means panel-off work on the evaporator side.
Pass along the model and the checks you ran, then open a visit request from this spot.
Book a visit
A simplified sketch, because the inside of a Viking differs by series. Tap a highlighted part for its photo and the matching test.
The thermistor at the evaporator outlet. This lamp pairing is reserved for the moment it is found disconnected or shorted.
Read the supporting manualTwo things: check the sensor and its attachment for abnormality, then start operation after the sensor part is repaired.
Read the supporting manualThe lamps act as a code. The chart reads the combination rather than each lamp alone, so a full reservoir does not rule the pattern out.
Read the supporting manualNo. Those rows describe the evaporator staying at 32 F or warmer, and Er01 blinks all three lamps. This row is about the sensor reading itself.
Read the supporting manualManufacturer document
Viking Range, LLC (official manual PDF)
Rev C, printed code (051525) / PDF p.17
FNIU515D guide, page 17 lamp chart: the evaporator-sensor pairing.
Not in this pairing. Read the two lamps as one signal that names the evaporator sensor, and leave the water line alone.
At the evaporator outlet inside the cabinet. No owner access is shown anywhere in the guide.
No guidance is printed. The sensor watches the cooling cycle, so switch the machine off while the pattern is lit and nobody is nearby.
Only a stray reading. If the sensor really is open or shorted, the lamps reappear as soon as the machine tries to make ice.
Viking codes, symptoms, parts, visits
Er01 on a Viking FNIU515D nugget ice machine means the evaporator is still 32 F or warmer after 30 minutes of ice making. The chart lists a refrigerant leak check, a sensor check, and restoring power once the cooling problem is solved.
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.
Book a diagnostic for your series at the appliance itself.
Office particulars and the entry details to give us.