What it means
A fully blank display on a Viking FIUI5152D drain-pump ice machine can mean the drain safety has cut power because the water level hit its high limit. Fix the restriction in the drain line and power returns by itself.
Viking ice maker Blank display (no icons) / Drain and pump
A fully blank display on a Viking FIUI5152D drain-pump ice machine can mean the drain safety has cut power because the water level hit its high limit. Fix the restriction in the drain line and power returns by itself.
Also shown as Blank display (no icons)
A fully blank display on a Viking FIUI5152D drain-pump ice machine can mean the drain safety has cut power because the water level hit its high limit. Fix the restriction in the drain line and power returns by itself.
Confirm the cord is seated and the circuit is live.
The display stays blank with the outlet live.
Your Viking checklist, kept on this device only

Confirm the cord is seated and the circuit is live. A dead outlet looks identical to a drain cut-out.

The manual says the pump keeps running during the cut-out. Wait a short while for the display to return with a start-up chime.

Look for kinks, a long unneeded loop, or a drain that does not end in an open air gap. Check that the vent tube on the back of the unit is open.

With the unit off, slowly pour three quarts of water into the bin. It should drain fully with no power cut. If the display blanks again, book a visit.
Pass along the model and the checks you ran, then open a visit request from this spot.
Book a visitA simplified sketch, because the inside of a Viking differs by series. Tap a highlighted part for its photo and the matching test.

Component reference
A Viking 5 Series nugget ice machine (FNIU515D) removes melt water with a drain pump that has its own reservoir.
Read the definitionOn drain-pump models, a high-limit condition interrupts power to prevent flooding. With no power, no icons show in the display area.
Read the supporting manualA start-up chime sounds, then a self-test runs and OFF appears in the display.
Read the supporting manualFixing what restricts the drain: no kinks, an open drain with an air gap, and an open vent tube on the back of the unit.
Read the supporting manualIt can. The troubleshooting page says the pump may briefly shut the unit off when a lot of water arrives. Wait a few minutes while the pump works.
Read the supporting manualManufacturer document
Viking Range, LLC (official manual PDF)
printed code (091426) / PDF p.10
Manufacturer document
Viking Range, LLC (official manual PDF)
printed code (091426) / PDF p.25
FIUI5152D guide: the drain test on page 10 and the troubleshooting list on page 25. Applies to drain-pump versions only.
Not by itself. The guide names the drain safety cut-out as one cause, and the display returns with a chime as the water level drops.
Only drain-pump models. Gravity-drain machines have no pump and no high-limit cut-out.
Yes. The guide wants the pump vent tube kept open so air moves as water enters the reservoir. A pinched tube slows draining.
Whether a chime sounded when the display returned, and how the drain line runs from the machine. Those two details point at the cause.
Viking codes, symptoms, parts, visits
CL alternating with ICE on a Viking FIUI5152D undercounter ice machine appears every 3000 cycles to say the unit needs cleaning. The reminder resets once the machine has finished its cleaning cycle.
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.
A Viking 5 Series nugget ice machine (FNIU515D) removes melt water with a drain pump that has its own reservoir. The pump turns on by itself as the reservoir fills, even in Sabbath mode. The Drain lamp lights when the drain valve opens, and Er16 means the water level sensor was not reached within 2 minutes of draining.
Book a diagnostic for your series at the appliance itself.
Office particulars and the entry details to give us.