What it means
NO WATER and DRAIN blinking together on a Viking FNIU515D mean its ice full sensor, down in the storage bin, has lost its connection or shorted out. It is a sensor error, not a water or drain problem. Book a visit.
Viking ice maker NO WATER and DRAIN lamps blinking / Temperature sensors
NO WATER and DRAIN blinking together on a Viking FNIU515D mean its ice full sensor, down in the storage bin, has lost its connection or shorted out. It is a sensor error, not a water or drain problem. Book a visit.
Also shown as NO WATER and DRAIN lamps blinking
NO WATER and DRAIN blinking together on a Viking FNIU515D mean its ice full sensor, down in the storage bin, has lost its connection or shorted out. It is a sensor error, not a water or drain problem. Book a visit.
NO WATER and DRAIN blink and ICE stays dark.
NO WATER and DRAIN are blinking again after a power cycle.
Your Viking checklist, kept on this device only

NO WATER and DRAIN blink and ICE stays dark. A lone blinking ICE lamp is the normal full-bin signal and needs nothing.

The ice full sensor lives in the storage bin. If the bin is stuffed with ice or a scoop is wedged in, empty it and see whether the lamps stop. Keep your hands out of any moving parts.

Turn the mode switch off, wait a minute, then back to ice. A broken lead on the bin sensor will show again as soon as the machine runs.

The chart prints no action for this row. A technician can check the sensor lead and the connector, which needs the machine unplugged and panels removed.
Pass along the model and the checks you ran, then open a visit request from this spot.
Book a visit
A simplified sketch, because the inside of a Viking differs by series. Tap a highlighted part for its photo and the matching test.
It tells the machine the bin has filled. When that bin sensor is disconnected or shorted, this is the pattern the chart assigns.
Read the supporting manualThe chart reads them as a pair, and ties this pairing to the bin sensor rather than to the water inlet or the drain pump.
Read the supporting manualOne ICE lamp that is lit for two seconds, then dark for one. Per the chart it goes out when the sensor again sees the release temperature.
Read the supporting manualNone. With no action on the row, the bin look and one restart are as far as you go before a visit.
Read the supporting manualManufacturer document
Viking Range, LLC (official manual PDF)
Rev C, printed code (051525) / PDF p.17
Same FNIU515D guide, lamp chart at page 17; the sensor in question sits inside the storage bin.
No. A blocked drain is Er16, with its own lamp pattern. With NO WATER and DRAIN blinking together, the chart reads a bin sensor problem.
A full bin shows as the slow ICE blink, not this pair. Still, empty the bin once, because ice jammed against the sensor can confuse the reading.
It is low risk, but a machine that cannot tell when the bin is full may overfill or stop. Unplug it if you see ice backing up.
In the air sensor row NO WATER is the one left dark; here it is ICE. That single lamp separates the two.
Viking codes, symptoms, parts, visits
Er16 on a Viking FNIU515D nugget ice machine is a water drain error: the lower limit water level sensor did not detect water within 2 minutes of the drain valve operating. The chart lists replacing the sensor and checking the drain valve.
On a Viking undercounter ice machine, little or no ice usually traces to the control position, the water supply, a blocked drain, a dirty condenser or scale on the evaporator. Check the switch and the water first, then clean the system. Book a technician if the bin stays empty.
Book a diagnostic for your series at the appliance itself.
Office particulars and the entry details to give us.